Look

By "seeing" to observe the appearance of the refrigerator at work to analyze the symptoms of malfunctions.

① Look at the frost on the surface of the evaporator. If the frosting on the surface of the evaporator is uneven or incomplete, it means that the refrigerant in the refrigeration system is insufficient and there are leakage points. If the frost layer on the surface of the evaporator is too thick, defrost in time or reset the defrost time.

②Look at the cooling rate of the freezer compartment. If the cooling rate is significantly lower than the original normal operation, it is because the refrigerator door is not tightly closed (the magnetic sealing strip is aging or damaged), the refrigeration system is lack of refrigerant, the condenser surface is too gray or the evaporator surface is frosted The layer is too thick. These will cause the compressor to work for a long time, and the temperature will drop very slowly.

③Look at the outer surface of the refrigeration system (especially the joints and the surface of the evaporator). If there is oil stains on the outer surface of the refrigeration system, it means there is leakage. The lighter case will cause the refrigeration capacity to decrease, the uneven or incomplete frosting on the evaporator surface, and the severer case will cause the refrigeration system to completely lose the refrigeration capacity.

④Look at the suction line on the compressor. If there is frosting or condensation on the gas pipeline, it may be caused by excessive refrigerant charge, or the frost layer of the evaporator is too thick, causing the refrigerant liquid to not vaporize well in the evaporator and reach the suction pipeline to further absorb heat. Defrost and dew. In severe cases, frost and condensation may appear on the compressor.


Listen

Listen to the operation of the refrigerator after it is energized, such as whether the motor is running, various sounds when the compressor is working, and whether the airflow sound in the evaporator is abnormal.

①Listen to the sound of the compressor working. When the power is turned on, you hear the "click" sound of the starter relay, the compressor motor can start at 0.2 ~ 0.5 S, and make the compressor work. There is no abnormal noise during operation, indicating the working status of the compressor and the motor. good.

If the compressor makes a "buzzing" sound during starting, and at the same time, you hear the contact of the start relay open, and the repeated "click" sound of the pull-in is accompanied by the violent vibration of the compressor, it means that the compressor is not put into operation. Operation, and there are serious failures. This is caused by reasons such as motor winding short circuit, open circuit, compressor mechanical failure, starting relay failure, and blockage of the high-pressure end pipeline of the refrigeration system, which causes the compressor to be overloaded.

If the compressor is running and you hear a "click" sound, it is a metal impact sound from the compressor, indicating that the internal moving parts are loose and the parts collide with each other.

If the compressor is running and hear the "hiss" airflow sound, it is caused by the compressor's exhaust buffer tube falling off or broken, resulting in the high-pressure airflow sound; if the compressor stops working, you can hear the "hiss" airflow sound. The obvious bleed sound of "hissing" is caused by the breakdown of the high and low pressure seals on the valve plate of the compressor, or the inadequate and damaged suction and exhaust valve plates, causing the airflow sound generated by the high-pressure side to the low-pressure side.

If the compressor makes a "dangdang" sound when it is running or when it stops working, it is caused by the breakage or fatigue deformation of the supporting spring in the compressor.

②Listen to the sound of refrigerant inside the evaporator. When the refrigeration system is working normally, you can hear the slight continuous "hissing" throttling sound of the refrigerant entering the evaporator through the capillary tube and the slight boiling and vaporizing sound of the boiling water in the evaporator, indicating that the refrigeration system is working normally .

If you can hear a slight "chicking" sound in the evaporator, and you can hear the occasional and occasional refrigerant throttling and the slight suction sound in boiling, then there is a small amount of water in the refrigeration system, causing the capillary tube It is caused by the occasional ice block at the exit location.

If you can hear all airflow sounds in the evaporator, it means that the refrigerant in the refrigeration system is basically leaking; if you can't hear the airflow sound in the evaporator, it means that the refrigeration system is blocked or there is no refrigerant in the refrigeration system. The leak is clean.

③Listen to the sound of the refrigeration system at work. When the refrigeration system is working normally, you can hear the sound of running water in the pipes of the system. If you can't hear any noise from the condenser, it is normal to hear "ice cracking" in the refrigerator box when it stops working.

If the refrigeration system is working, when the surface temperature of the evaporator drops to about -20 degrees, there will be a large abnormal noise in the condenser, which is high and low, and the sound of suction is smooth when it is blocked. At the same time, you can hear Sometimes there are no vibrations when holding the suction tube. It is due to the addition of different specifications and models of refrigerating oil or poor quality of refrigerating oil, and too much water content causes waxing of the capillary tube and oil blockage.

④Listen to the overall sound of the refrigerator. ~ A better refrigerator should not make any abnormal noises during operation. If the refrigerator makes abnormal noises during use, the main reason is that the refrigerator is not installed securely, and the fastening screws are loose, causing the refrigeration pipe to vibrate. If the shelf in the refrigerator box is not placed flat, the stored items will not be placed securely, and the inner wall of the refrigerator will cause noise. These can be eliminated by corresponding measures.


Touch

Feel the temperature changes of various parts of the refrigerator refrigeration system during operation to judge and analyze whether the refrigerator is working normally and where the fault occurs.

① Touch the temperature of the compressor during operation. The temperature of the compressor housing can be referred to Table 4-10. Generally, when the indoor ambient temperature is below 30℃, the surface temperature of the compressor housing should not be hot to your hands, but it is normal that your hands can keep your hands on; if the compressor housing temperature exceeds At 80°C, the hands cannot be kept on it and it is very hot. At this time, the compressor discharge temperature can reach 130°C or more. If the compressor is not malfunctioning and the refrigerant charge is appropriate, the condenser is too dirty or the ventilation and heat dissipation are too poor. If the compressor has been working for a period of time, and the temperature of the compressor shell feels cold or is similar to the temperature of the human body when touching the compressor, the refrigeration system has no refrigerant. If the refrigeration system lacks refrigerant or the heat load increases, the compressor temperature will be too high.

② Touch the surface temperature of the condenser and exhaust pipe.

If the outer surface temperature of the first three or four tubes on the surface of the condenser is high, the outer surface temperature of the last tube is lower than that of the previous tubes. It is close to the indoor ambient temperature or has a warm feeling, indicating that the condenser is working Normal; if the entire condenser pipe is hot and hot, it means that the refrigeration system is filled with too much refrigerant or there is air in the refrigeration system.

b. Touch the surface of the exhaust pipeline by hand. In normal working conditions, the outer surface of the exhaust pipeline has a high temperature, which is hot in summer and hot in winter; if there is no temperature, the refrigeration system has no refrigerant.

③ Touch the surface temperature of the drying filter and capillary. Under normal working conditions, the surface temperature of the filter drier and capillary tube should be similar to that of the indoor environment. The outer surface of the filter drier and capillary tube should be slightly warm when touched by hand, and there should be no significant temperature difference before and after the filter drier and capillary tube are touched by hand. If there is a temperature difference or lower than the ambient temperature, there is frosting or condensation, it means that the mesh in the filter dryer has been blocked or the capillary tube has been blocked.

④ Touch the surface of the evaporator. When the refrigeration system is working normally for about 15-20 minutes, the surface of the evaporator should have a uniform layer of frost when touched by hand. When you touch it with your fingers in water, there will be an obvious sticky feeling, indicating that the cooling effect is very good. If the frost on the surface of the evaporator will fall off with the touch of your hand, it is a virtual frost. If there is condensation or frost on the suction pipe, it means that the refrigeration system has been charged with too much refrigerant; if the surface of the evaporator is not frosted Uniformity, or frost on the front half and condensation on the back half, the refrigeration system is insufficiently charged with refrigerant, or the capillary tube and the drying filter are clogged; if condensation appears on the surface of the evaporator or there is no condensation or frost, then It is because the refrigerant in the refrigeration system has basically leaked out, or the refrigeration system is seriously blocked.

⑤ Touch the outer surface of the components, pipes, connections, welding joints, etc. in the refrigeration system. Under normal circumstances, there should be no oil stains on these external surfaces. If there is oil stains on the hand-touched part, it means that there is leakage in this part.


The Amount

Use instrumentation tools to measure the voltage, working current, temperature and pressure of the refrigerator to determine and analyze the fault location, and further prove the accuracy of seeing, listening, and touching, which has the actual effect of getting twice the result with half the effort.

①Measure the voltage and working current of the refrigerator.

Using a multimeter to measure the voltage of the refrigerator should be within the calibration (220±10%) V range. It is worth noting that although various brands of refrigerators have given the requirements for the voltage range of the electricity, the refrigerator has been in the power supply voltage for a long time. If the highest or lowest edge work within the required range, the failure rate will increase accordingly, and the electrical components in the refrigerator are most likely to be damaged, especially the compressor motor is most likely to be burned due to excessively high or low voltage.

Using a clamp-on ammeter to measure the working current of the refrigerator should not exceed the rated current on the nameplate. If it exceeds or approaches the rated current on the nameplate, there are serious hidden dangers to the normal use of the refrigerator.

a. Measure the starting current of the compressor. The normal starting current of the compressor is about 7-8 times the rated current, and the starting work is completed within 0.2-0.5 s. If the rated current on the nameplate of the refrigerator is 0.9 A, the normal instantaneous starting current should be about 7 A; If the starting current reaches more than 8 A, the starting current is too high. If the starting time of the compressor is long and the starting current is too high, it indicates that the starting winding has a short circuit between turns, or there are faults such as the compressor shaft holding, cylinder jam, and high-pressure exhaust pipe blockage. If the starting current is too low (except for PTC starting components), when the starting current is lower than four-fifths of the normal starting current, the compressor cannot start and run normally, indicating that the compressor motor winding is open.

b. Measure the operating current of the compressor. If the operating current of the compressor is too high, it means that the refrigeration system is filled with too much refrigerant, there is air in the refrigeration system, the condenser is too dirty or the heat load is too large, etc.; if the compressor is running at a low operating current, it means Lack of refrigerant in the refrigeration system or clogging of the filter drier and capillary tube.

c. The ohmic resistance of the quantity control circuit. Use the ohm block of a multimeter to measure the resistance of each component of the control circuit, you can quickly find the fault location and damaged electrical components in the circuit, and replace and repair them in time.

②The pressure and temperature of the refrigeration system

a. Use a pressure gauge to measure the pressure of the refrigeration system. Connect a low-pressure pressure gauge to the repair valve connected to the compressor charging pipe to measure the suction pressure of the compressor during operation. For example, the temperature of the freezer compartment of a refrigerator should reach about -18°C. If the measured suction pressure exceeds If it is high, it means that the refrigerant is charged too much; if the suction pressure is too low, it means that the refrigerant is insufficient or the filter drier and capillary are blocked. When the indoor ambient temperature is about 30°C, if a high-pressure pressure gauge can be connected to the compressor's discharge pipeline, the discharge pressure can be measured to be about 7.5 kPa/cm2. If the exhaust pressure is too high, it means that the refrigerant is charged too much, the refrigeration system has air or the condenser is too dirty; if the exhaust pressure is too low, it means that there is a lack of refrigerant or no refrigerant and the capillary of the dryer filter is clogged.

b. Use a thermometer to measure the temperature of various parts of the refrigeration system and the temperature of the freezer and refrigerator compartments. Use the thermometer probe close to the outer surface of the part to be measured in the refrigeration system to minimize the influence of the ambient temperature on the temperature probe, so as to judge whether the refrigeration system is working normally. Refer to Figure 4-11 for the temperature of each part of the refrigeration system. Place the thermometer in the freezer and refrigerator, and actually measure whether the temperature in the freezer and refrigerator is within the scope of use requirements.

③The start and stop time of the volumetric compressor

The start and stop time of the compressor directly affects the use effect of the refrigerator. In use, it is hoped that the compressor running time is as short as possible, and the stopping time is as long as possible, so as to save energy. When measuring the compressor start and stop time, the temperature controller knob can be turned to the 3rd gear position as a measurement reference point to compare the compressor start and stop time of the refrigerator. The normal compressor start-to-stop time ratio is 1:2~1:3 in summer and 1:3~1:5 in winter. For example, when the indoor ambient temperature is about 20℃, the compressor should run for about 10 minutes and stop working for more than 30 minutes if the requirements of the freezer and cold storage rooms are met. Its start-stop ratio is 1:3. normal. By measuring and comparing the length of the compressor's start and stop time, it can be judged whether the refrigerator is in good working condition, whether the refrigerator door is tightly sealed, or whether the refrigeration system is faulty, etc.


Smell

Use your nose to smell the electrical components of the refrigerator in use for abnormal odors, such as burning and other odors, to determine whether the electrical components are damaged, whether the wiring is loose, or sparking; The smell is used to judge whether the items stored in the box are corrupted, and the box should be cleaned in time, especially the corruption in the freezer will corrode the surface of the evaporator, causing leakage of the evaporator. Attention should be paid.


Ask

During the maintenance, learn from the user about the use of the refrigerator, the items stored, and when and under what circumstances the refrigerator failed. Further analysis infers whether the refrigerator is malfunctioning due to improper use or other reasons. Excluding the external factors that cause the malfunction is conducive to eliminating the malfunction of the refrigerator as soon as possible.